Please use this identifier to cite or link to this item:
https://idr.l2.nitk.ac.in/jspui/handle/123456789/12875
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Jayalekshmi, B.R. | |
dc.contributor.author | Chinmayi, H.K. | |
dc.date.accessioned | 2020-03-31T08:42:19Z | - |
dc.date.available | 2020-03-31T08:42:19Z | - |
dc.date.issued | 2016 | |
dc.identifier.citation | Earthquake and Structures, 2016, Vol.10, 1, pp.191-209 | en_US |
dc.identifier.uri | http://idr.nitk.ac.in/jspui/handle/123456789/12875 | - |
dc.description.abstract | Seismic codes are the best available guidance on how structures should be designed and constructed to ensure adequate resistance to seismic forces during earthquakes. Seismic provisions of Indian standard code, International building code and European code are applied for buildings with ordinary moment resisting frames and reinforced shear walls at various locations considering the effect of site soil conditions. The study investigates the differences in spectral acceleration coefficient (Sa/g), base shear and storey shear obtained following the seismic provisions in different codes in the analysis of these buildings. Study shows that the provision of shear walls at core in low rise buildings and at all the four corners in high rise buildings gives the least value of base shear. 2016 Techno-Press, Ltd. | en_US |
dc.title | Seismic force evaluation of RC shear wall buildings as per international codes | en_US |
dc.type | Article | en_US |
Appears in Collections: | 1. Journal Articles |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.